<mods:mods version="3.3" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd" xmlns:mods="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"><mods:titleInfo><mods:title>Penyisihan Kadar Amonia Total Fenol dan Suklfida Pada Air Limbah Batik Menggunakan Ipal Berbasis Elektrokoagulasi</mods:title></mods:titleInfo><mods:name type="personal"><mods:namePart type="given">Greece Tina</mods:namePart><mods:namePart type="family">Jayanti</mods:namePart><mods:role><mods:roleTerm type="text">author</mods:roleTerm></mods:role></mods:name><mods:abstract>Elimination of Total Ammonia, Phenol and Sulfide Levels in Batik Wastewater&#13;
Using Electrocoagulation-Based WWTP&#13;
Grace Tina Jayantia*), Sutantob), Muhammad Fathurrahmanb)&#13;
a) Department of Chemistry, Faculty of Mathematics and Natural Sciences, Pakuan University, Bogor Indonesia&#13;
b) Department of Chemistry, Faculty of Mathematics and Natural Sciences, Pakuan University, Bogor Indonesia&#13;
*) Corresponding Author: gracetinaj29@gmail.com&#13;
DOI: ...&#13;
Article history: received ....; revised ....; accepted ...; published ....&#13;
ABSTRACT&#13;
Electrocoagulation-based batik WWTP has been designed to assist batik artisans in reducing water pollution.&#13;
This study aims to determine the optimal dilution factor to obtain the effectiveness of parameter level&#13;
elimination, namely total ammonia, phenol and sulfide, as well as the effectiveness of parameter elimination&#13;
that affects other wastewater quality, including COD, DO, TSS, DHL, pH, and color (Pt-Co scale). The&#13;
processing process is carried out using an electrocoagulation reactor measuring 5900 mL equipped with 4&#13;
aluminum electrodes spaced 4 cm apart. The electrode is conducted with a direct electric current of 2-8 A at a&#13;
voltage of 24 volts. The test results are compared with the standard standard of PERMENLH/BPLH No. 12 of&#13;
2025. The results of the study showed that at 2x EC II dilution, it was the most optimal condition. Under this&#13;
condition, the total ammonia allowance reached 83.23%, phenol 67.94%, sulfide 100%, COD 89.90%, BOD&#13;
87.92%, TSS 81.76%, DHL 77.45%, color scale (Pt-Co) 93.91%, and DO increased by 38.18%.&#13;
Keywords: total ammonia, electrocoagulation, phenol, sulfide, batik wastewater</mods:abstract><mods:classification authority="lcc">Kimia</mods:classification><mods:originInfo><mods:dateIssued encoding="iso8061">2026-01-21</mods:dateIssued></mods:originInfo><mods:originInfo><mods:publisher>Universitas Pakuan;Fakultas Matematika dan Pengetahuan Alam</mods:publisher></mods:originInfo><mods:genre>Thesis</mods:genre></mods:mods>